Login|Register|Forget password|Dashboard Back to Home|Contact|Shopcart
Unverified1st Year

Shenzhen Puzhesi Technology Co., Ltd.  

Consumer Electronics,Electrical & Electronics,Security & Protection,Service

Search
新闻中心
  • 暂无新闻
产品分类
  • 暂无分类
联系方式
  • 联系人:Miss Eleanor Lu
  • 电话:86-755-27348356
  • 传真:86-755-89479563
站内搜索
 
荣誉资质
  • 暂未上传
友情链接
  • 暂无链接
首页 > Products > 2 Zone Conventional Fire Alarm Control Panel for Factory and Restaurant
2 Zone Conventional Fire Alarm Control Panel for Factory and Restaurant
单价 $85.00 / Box对比
询价 暂无
浏览 84
发货 Chinaguangdongshenzhen
库存 500000Box
过期 长期有效
更新 2020-08-04 06:46
 
详细信息
Product Name: 2 Zone Conventional Fire Alarm Control Panel for Factory and Restaurant Model NO.: CP1002 Wiring Mode: Sub-Line System Receive Frequency: 485/232 Networking Mode: Alarm Alarm Volume (within 1m): ?90dB Certification: CE Usage: Fire, Smoke Function: Networked Type: Fire Alarm Host Weight: 2.2kg Primary AC: 90-270VDC Number of Zone: 2 Zone Color: Red Maxinum Number of Detectors: 30 Trademark: panel Transport Package: Carton Specification: 370*440*100mm Origin: China HS Code: 8531100000 Product Description 2 zone panel have Master panel and Slave panel. One Master panel can connect 31 Slave panel, and the Master panel could show the fire and fault of all slave panel. The slave panel can only show itself fire and fault.Key Specifications/Special FeaturesFour Style B (Class B) Initiating Device Circuits (IDCs).One Master Panel also has two zones, each zone can connect max.25 conventional detectors.One slave Panel has two zones, each zone can connect max.25 conventional detectors.The Mater panel could show the fire and fault of all slave panel. The slave panel can only show itself fire and fault.Mini size as 108X143X40mmMaster panel has 4 digital LED display to show slave number and status.2 Detection Zones Panel, 25 Detectors per ZoneFire 1 relay would be activated when one zone alarms.Fire 2 relay would be activated after 30 seconds delay when two zones alarm.1 Sound relay output for sound alarm1 Fault relay output for fault conditionZones Fire and Fault LEDs indicationFire1, Fire2, Sound relay outputs can be activated manuallyRS485 Port for repeater up to 1.2KmUp to 31 Slave panels can be connected to one Master panelPowered by outside DC22-26V power supplyEnd Of Line Status Detection, Short circuit /open circuit detectionTwo modules power supply could be selected.The power supply input is AC90-270VTwo 4AH batteries can be housed in the power supply cabinet.Relay output contacts rated at: 2.0 amps @ 30 VDC.